American Electrical
Testing Co.,Inc.
480 Neponset Street, Bldg. 3
P.O. Box 267 Canton, MA 02021
EMail: info@99aetco.com
Telephone: 800-99AETCO
General Business:
8 a.m.- 4:30 p.m. EST
781-821-0121
Copyright® 2005 American Electrical Testing Co., Inc.
Last Modified: Jan. 2005
Power User
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
-
- ACCEPTANCE TESTING, COMMISSIONING & START-UP SERVICES
Acceptance testing, commissioning, startup and maintenance ensures that it is safe to energize, meets specifications and the equipment is operating in accordance with its intended design.
ENGINEERING SERVICES
Knowledgeable Engineers with "Hands on Experience" provide Power Quality Surveys, One Line Diagrams, Field Verification, Creation & Updates on CAD,Short Circuit & Coordination Studies, Harmonic Studies, Load studies and PLC Programming (Systems Integration).
PREVENTIVE & PREDICTIVE MAINTENANCE PROGRAMS
Custom designed PM programs take into account equipment condition, environmental considerations, safety, and the criticalness of the component or subsystem of the overall system.
-
-
-
- INFRARED SURVEYS
Infrared surveys are useful in any application where a temperature difference can be used to identify problem areas.
-
|
|
|
|
|
|
|
|
|
|
|
ENGINEERING SERVICES
Systems Studies
Short Circuit &
Coordination Studies
Load Flow/Voltage Drop
One-Line Drawings (CAD)
Power Quality
Harmonics Measurement
Voltage Disturbance Analysis
Power Metering
SCADA
Preventative & Maintenance Programs
Managed Maintenance Programs
Resident Engineer- Constr. Management
System Startup
Troubleshooting
Design Services
Compliance Engineering
SWITCHGEAR
Infrared Scanning
Bus Duct/Risers
Functional
Insulation resistance
TRANSFORMERS
Oil ATM Screen Tests
Dissolved Gas in Oil Analysis
Turns Ratio Test
Dielectric Absorption/PI Index
Insulation Power Factor (DOBLE)
Transformer/Bushings
Oil/Excitation
Load Tap-Changer Service
Oil Reclamation
CABLE TESTING: LOW/MEDIUM/HIGH VOLTAGE
Hipot
Insulation Power Factor (DOBLE)
Dielectric Absorption
Insulation Resistance
Shield Continuity
Cable Route Tracing
Fault Locating
SWITCHES: LOW/MEDIUM/HIGH VOLTAGE
Contact Resistance
Insulation Resistance
Functional
Adjustment
Mechanical
Oil SF6
CIRCUIT BREAKERS: LOW VOLTAGE
Primary Current Injection
Secondary Injection
Contact Resistance
Insulation Resistance
Functional
Retrofits- Solid State
Rebuilding
CIRCUIT BREAKERS: MEDIUM/HIGH VOLTAGE
Contact Resistance
Time/Motion Analysis
Insulation Power Factor
Oil/SF6
Vacuum
Leak Testing and Repair
Functional
Repairs
|
|
NETWORK PROTECTORS
Testing
Maintenance
Overhauls
Repairs
PROTECTIVE RELAYS
Functional Testing
Operational Testing
Calibration
INSTRUMENT TRANSFORMERS
CT,VT,PT,CCVT
Ratio & Polarity
Burden/Saturation
Insulation Power Factor
INSTRUMENTATION (I&C)
Electrical- KWH,A,VpF,Hz.,SS,KW,KVAr,KVA
Process Control- Press, Temp. Flow, RPM, 4-20MA
Resistance Temp. Detectors (RTD)
Calibration
Functional Testing
Rescaling
REGULATORS
GROUND SYSTEMS
Earth Resistivity Studies
Grid Resistance Measurements
GFI Calibration
ROTATING MACHINERY:
SYNCHRONOUS/INDUCTION GENERATORS & MOTORS
Motor Control Centers
Insulation Power Factor
Dielectric Absorption
Polarization Index
Load Testing
Field Resistance
Tipup Tests
Voltage Regulator Calibration
Vibration Analysis
BATTERY SYSTEMS
AC Impedance Measurements
DC Voltage Measurements
Specific Gravity
Load Testing
Charger Calibration
Trending
EMERGENCY SYSTEMS
Engine Generator
Uninterruptible Power Systems
Automatic Transfer Switches
Emergency Lighting
POWER LINE CARRIER SERVICES
LONG TERM STAFFING
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|